021-612 3131 / 0812 9726 3131 cs@platinum-computer.com
Select Page

UPS APC 8000XLI

gambar UPS APC 8000XLI

Smart-UPS On-Line Features & Benefits

Availability
Automatic internal bypass
Supplies utility power to the connected loads in the event of a UPS power overload or fault.
Scalable runtime
Allows additional run time to be quickly added as needed.
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.
Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage according to battery temperature.

Manageability
Network manageable
Provides remote power management of the UPS over the network.
InfraStruXure Manager Compatible
Enables centralized management via the APC InfraStruXure Manager.
SmartSlot
Customize UPS capabilities with management cards.
LED status indicators
Quickly understand unit and power status with visual indicators.
Serial connectivity
Provides management of the UPS via a serial port.

Adaptability
Plug-and-Play external batteries
Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS.
Rack/Tower convertible
Protects the initial investment in the UPS when migrating from tower to rack-mount environment.
Flash upgradeable firmware
Install maintenance releases of firmware remotely using FTP.

Serviceability
User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Predicitive failure notification
Provides early-warning fault analysis ensuring proactive component replacement.
Disconnected battery notification
Warns when a battery is not available to provide backup power.
Audible alarms
Provides notification of changing utility power and UPS power conditions

Protection
Frequency and voltage regulation
Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
Power conditioning
Protects connected loads from surges, spikes, lightning, and other power disturbances.
Input power factor correction
Minimizes installation costs by enabling the use of smaller generators and cabling.
Generator compatible
Ensures clean, uninterrupted power to protected equipment when generator power is used.
Cold-start capable
Provides temporary battery power when the utility power is out.
Resettable circuit breaker
Easy recovery from overloads; no need to replace a fuse.
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.

Specifications APC UPS SURT8000XLI

Output Power Capacity
6400 Watts / 8000 VA , Max Configurable Power
6400 Watts / 8000 VA , Nominal Output Voltage
230V ,

Output Voltage Note
Configurable for 220 : 230 or 240 nominal output voltage , Output Frequency (sync to mains)
50/60 Hz +/- 3 Hz user adjustable +/- 0.1 , Other Output Voltages
220, 240 ,

Topology
Double Conversion Online , Bypass
Internal Bypass (Automatic and Manual) ,
Nominal Input Voltage
230V ,

Input Frequency
50/60 Hz +/- 5 Hz (auto sensing) ,
Battery Type
Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof , Included Battery Modules
4 ,

Typical recharge time
2.20 hour(s) ,
Interface Port(s)
DB-9 RS-232, RJ-45 10/100 Base-T, Smart-Slot , Control panel
LED status display with load and battery bar-graphs and On Line : On Battery : Replace Battery : Overload and Bypass Indicators , Audible Alarm
Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm , Emergency Power Off (EPO)
Yes ,
Standard Warranty
2 years repair or replace

Output Power Capacity
6400 Watts / 8000 VA ,

Max Configurable Power
6400 Watts / 8000 VA ,

Nominal Output Voltage
230V ,

Output Voltage Note
Configurable for 220 : 230 or 240 nominal output voltage ,

Output Frequency (sync to mains)
50/60 Hz +/- 3 Hz user adjustable +/- 0.1 ,

Other Output Voltages
220, 240 ,

Topology
Double Conversion Online,

Bypass
Internal Bypass (Automatic and Manual) ,

Nominal Input Voltage
230V ,

Input Frequency
50/60 Hz +/- 5 Hz (auto sensing) ,
Battery Type
Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof ,

Included Battery Modules
4 ,

Typical recharge time
2.20 hour(s) ,

Interface Port(s)
DB-9 RS-232, RJ-45 10/100 Base-T, Smart-Slot ,

Control panel
LED status display with load and battery bar-graphs and On Line : On Battery : Replace Battery : Overload and Bypass Indicators ,

Audible Alarm
Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm ,

Emergency Power Off (EPO)
Yes ,

Standard Warranty
2 years repair or replace

Kata Kunci Terkait :