021-612 3131 / 0812 9726 3131 cs@platinum-computer.com
Select Page

MGE Galaxy 7000 300 kVA – G7TUPS300

gambar ups apc MGE Galaxy 7000 300 kVA G7TUPS300

UPS MGE Galaxy 7000 G7TUPS300

MGE Galaxy 7000 300 kVA – G7TUPS300
A high-adaptability, 3-phase UPS that meets the unique requirements of medium to large data centers, industry, buildings, and mission-critical environments. This UPS includes ECO Mode, with cost-saving energy efficiency, and SPoT operation mode, which increases on-site test capability without additional load bank.

G7TUPS300 Features
MGE Galaxy 7000 300 kVA
Audible alarms
Provides notification of changing utility power and UPS power conditions
Generator compatible
Ensures clean, uninterrupted power to protected equipment when generator power is used.
Manual maintenance bypass
Reduces installation costs by eliminating the need for an external mechanical bypass.

MGE Galaxy 7000 Features & Benefits
Economy
ECO Mode
Operating mode that by-passes unused electrical components in good power conditions to achieve high operating efficiency without sacrificing protection
Fully-rated power kVA equals kW
Reduces cost by eliminating the need for an oversized UPS for Power Factor Corrected (PFC) loads.
Advanced electrical features
Excellent power conditioning, very low harmonic distortion through IGBT rectifier, input power factor correction, and high power efficiency

Availability
High availability architecture
Different running modes : hot stand-by, integrated parallel, or centralized static switch for multi-modules leading to availability architectures

Manageability
Network management capability
Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet.

Compatibility
Parallel capability
Multiple units can be placed in parallel to meet power capacity and redundancy requirements
Output synchronization to external source
UPS systems can be synchronized with any other independent source for use with downstream static transfer switches.

Specifications MGE Galaxy 7000 300 kVA – G7TUPS300

Output

Output power capacity

270.0 KWatts / 300.0 kVA

Max Configurable Power (Watts)

270.0 KWatts / 300.0 kVA

Nominal Output Voltage

400V 3PH

Neutral Output Current

Output Voltage Note

Configurable for 380 : 400 or 415 V 3 Phase nominal output voltage

Output Voltage Distortion

Less than 2%

Output Frequency (sync to mains)

50 Hz, 60 Hz

Output Frequency (not synced)

60Hz +/- 0.1% for 60Hz nominal, 50Hz +/- 0.1% for 50Hz nominal

Other Output Voltages

380, 415, 440

Load Crest Factor

2.5 : 1

Topology

Double Conversion Online

Waveform type

Sine wave

Maximum Output Current

Output Connections

(1) Hard Wire 4-wire (3PH – PEN) (Battery Backup)

(1) Hard Wire 3-wire (3PH) (Battery Backup)

(1) Hard Wire 5-wire (3PH + N + G) (Battery Backup)

(1) Hard Wire 4-wire (3PH + N) (Battery Backup)

(1) Hard Wire 4-wire (3PH + G) (Battery Backup)

Output Voltage THD

< 2% linear load and <3% non-linear load

Bypass

Built-in Maintenance Bypass

Input

Nominal Input Voltage

400V 3PH

Input frequency

45 – 65 Hz

Input Connections

Hard Wire 5-wire (3PH + N + G)

Input voltage range for main operations

340 – 460 (400V) V

Input Total Harmonic Distortion

Less than 3% for full load

Type of Input Protection Required

3-pole breaker

Other Input Voltages

380, 415, 450

Maximum Short Circuit Withstand (Icw)

200.0 kAmps

Maximum Input Current

442.0 A

Input Power Factor at Full Load

1.0

Battery

Battery type

VRLA

Communication & Management

Pre-Installed SmartSlotâ„¢ Cards

AP9635CH

Control panel

Multi-function LCD status and control console

Audible Alarm

Audible and visible alarms prioritized by severity

Emergency Power Off (EPO)

Yes

Available SmartSlotâ„¢ Interface Quantity

1

Physical

Maximum Height

1900 mm , 190.0 CM

Maximum Width

1412 mm , 141.2 CM

Maximum Depth

855 mm , 85.5 CM

Net Weight

960.0 KG

Shipping weight

980.0 KG

Shipping Height

2030 mm , 203.0 CM

Shipping Width

1520 mm , 152.0 CM

Shipping Depth

960 mm , 96.0 CM

Color

Grey

# of Layers per Pallet

1.0

# of Units per Layer per Pallet

1.0

Environmental

Operating Environment

0 – 35 °C

Operating Relative Humidity

20 – 80 %

Operating Elevation

0-999.9 meters

Storage Temperature

-25 – 40 °C

Storage Relative Humidity

20 – 80 %

Storage Elevation

0-9000 meters

Audible noise at 1 meter from surface of unit

70.0 dBA

Protection Class

IP 20

Conformance

Approvals

CE, EN 60950, EN/IEC 62040-2, EN/IEC 62040-3, ISO 14001, ISO 9001, LCIE, VFI-SS-111

Standard warranty

1 year repair or replace

General

Bypass Connection

4 wire (3Ph + N) or 5 wire (3Ph + N + G)

Bypass Protection Device

630.0

Max Bypass Input Current

506.0 A