APC Smart-UPS RT 10,000VA RM 230V (SURT 10000 RMXLI)
APC Smart-UPS RT 10,000VA RM 230V
Rack-optimized models are an ideal choice for space constrained environments. With capacity up to 10kVA in a convenient rack-mountable 6U form, users can support power hungry blade servers or heavily loaded equipment racks. Customers looking for extremely tight voltage and frequency regulation, internal bypass, and input power factor correction will find them in the Smart-UPS RT.
Specifications APC Smart-UPS RT 10,000VA RM 230V (SURT 10000 RMXLI)
Product Description |
APC Smart-UPS RT 1000VA RM |
Device Type |
UPS – rack-mountable |
Rack Size |
6 U |
Input Voltage |
230 V |
Output Voltage |
230 V |
Battery |
Lead Acid |
Dimensions (WxDxH) |
43.2 cm x 66.3 cm x 26.3 cm |
Weight |
110.91 kg |
Manufacturer Warranty |
2 years warranty |
Run Time (Up To) |
4 min at full load |
Â
Details Specifications
Availabilty |
|
Automatic internal bypass |
Supplies utility power to the connected loads in the event of a UPS overload condition or fault. |
Scalable runtime |
Allows additional run time to be quickly added as needed. |
Intelligent battery management |
Maximizes battery performance, life, and reliability through intelligent, precision charging. |
Hot-swappable batteries |
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced |
Automatic restart of loads after UPS shutdown |
Automatically starts up the connected equipment upon the return of utility power. |
Temperature-compensated battery charging |
Prolongs battery life by regulating the charge voltage according to battery temperature. |
Manageability |
|
Network manageable |
Provides remote management of the UPS over the network. |
InfraStruXure Manager compatible |
Enables centralized management via the APC InfraStruXure® Manager. |
SmartSlot |
Customize UPS capabilities with management cards. |
LED status indicators |
Quickly understand unit and power status with visual indicators. |
Serial Connectivity |
Provides management of the UPS via a serial port. |
Adaptability |
|
Plug-and-Play external |
Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS. |
Rack/Tower convertible |
Protects the initial investment in the UPS when migrating from tower to rack-mount environment. |
Flash-upgradeable firmware |
Easy implementation of new firmware upgrades. |
Serviceability |
|
User-replaceable batteries |
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR) |
Automatic self-test |
Periodic battery self-test ensures early detection of a battery that needs to be replaced. |
Predictive failure notification |
Provides early-warning fault analysis ensuring proactive component replacement. |
Disconnected battery notification |
Warns when a battery is not available to provide backup power. |
Audible alarms |
Actively let you know if the unit is on battery, if the battery is low or if there is an overload |
Protection |
|
Frequency and voltage regulation |
Gives higher application availability by correcting poor frequency and voltage conditions without using the battery. |
Power conditioning |
Protects connected loads from surges, spikes, lightning, and other power disturbances. |
Input power factor correction |
Minimizes installation costs by enabling the use of smaller generators and cabling. |
Generator compatible |
Ensures clean, uninterrupted power to the loads in the event of an extended power outage |
Cold-start capable |
Provides temporary battery power when the utility power is out. |
Resettable circuit breakers |
Enables a quick recovery from overload events. |
Safety-agency approved |
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment. UL, FCC, CE, C-Tick approvals. |