APC Smart-UPS RC 3000VA – (SRC3000XLI)
UPS APC SRC3000XLI
SRC3000XLI Features
APC Smart-UPS RC 3000VA 230V
High density, double-conversion on-line power protection with scalable runtime
Includes: CD with software , Smart UPS signalling RS-232 cable , User Manual
Dataline surge protection
Provides protection of connected equipment from power surges on the data lines.
Smart-UPS On-Line Features & Benefits
Adaptability
Rack/Tower convertible
Protects the initial investment in the UPS when migrating from tower to rack-mount environment.
Flash upgradeable firmware
Install maintenance releases of firmware remotely using FTP.
Plug-and-Play external batteries
Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS.
Manageability
Serial connectivity
Provides management of the UPS via a serial port.
LED status indicators
Quickly understand unit and power status with visual indicators.
Network manageable
Provides remote power management of the UPS over the network.
SmartSlot
Customize UPS capabilities with management cards.
InfraStruXure Manager Compatible
Enables centralized management via the APC InfraStruXure Manager.
Protection
Generator compatible
Ensures clean, uninterrupted power to protected equipment when generator power is used.
Frequency and voltage regulation
Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Resettable circuit breaker
Easy recovery from overloads; no need to replace a fuse.
Power conditioning
Protects connected loads from surges, spikes, lightning, and other power disturbances.
Cold-start capable
Provides temporary battery power when the utility power is out.
Input power factor correction
Minimizes installation costs by enabling the use of smaller generators and cabling.
Serviceability
Audible alarms
Provides notification of changing utility power and UPS power conditions
User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Predicitive failure notification
Provides early-warning fault analysis ensuring proactive component replacement.
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Disconnected battery notification
Warns when a battery is not available to provide backup power.
Marketing Features
Low operating and maintenance costs with proven reliability and intelligent battery management.
Intelligent battery management, pioneered by APC, maximizes battery performance and life through intelligent, precision temperature compensated charging. Automatic self tests insure battery reliability and warn customers in advance of battery replacement. Convenient, easy to connect, hot-swappable battery modules provide battery replacement without powering down.
Save time with easy and convenient remote accessibility.
Network manageable via serial, USB or optional Ethernet. Includes Powerchute® Network Shutdown Software for convenient monitoring and control, safe operating system shutdown, and innovative energy management capabilities.
Peace of mind that comes with full equipment compatibility and reliability of a leader
Provides pure sine wave output which is recommended by server manufacturers using active power factor corrected (PFC) power supplies. Safety agency tested and approved means that you can deploy Smart-UPS with confidence that they meet or exceed the industry’s most rigorous standards.
Avoids costly power problems by keeping your IT equipment and data protected and available.
Network grade power conditioning protects from damaging surges and disruptive noise. The double conversion architecture provides tight voltage regulation, frequency regulation ,and zero transfer time to battery during power events.
Availability
Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Scalable runtime
Allows additional run time to be quickly added as needed.
Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.
Automatic internal bypass
Supplies utility power to the connected loads in the event of a UPS power overload or fault.
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage according to battery temperature.
Specifications APC Smart-UPS RC – SRC3000XLI
Output |
|
Bypass |
Built-in Bypass |
Load Crest Factor |
3 : 1 |
Output Voltage Distortion |
Less than 3% |
Efficiency at Full Load |
89.0 % |
Output Frequency (sync to mains) |
50/60 Hz +/- 3 Hz user adjustable +/- 0.1 |
Output Connections |
(8) IEC 320 C13 (Battery Backup) |
Other Output Voltages |
220 |
Max Configurable Power (Watts) |
2.1 KWatts / 3.0 kVA |
Output power capacity |
2.1 KWatts / 3.0 kVA |
Topology |
Double Conversion Online |
Output Voltage Note |
Configurable for 220 or 230V nominal output voltage |
Waveform type |
Sine wave |
Input |
|
Cord Length |
2.44 meters |
Efficiency at Full Load |
89.0 % |
Input frequency |
50/60 Hz +/- 5 Hz (auto sensing) |
Input voltage adjustable range for mains operation |
100 – 280 V |
Input voltage range for main operations |
160 – 280 V |
Input Breaker Capacity |
20 A |
Other Input Voltages |
220 |
Input Connections |
IEC-320 C20 |
Rack Height |
4 U |
Battery |
|
Battery Slots Empty |
1 |
Included Battery Modules |
1 |
Typical recharge time |
2 hour(s) |
Battery type |
Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof |
Extendable Run Time |
1 |
Replacement Battery |
SRC96XLBP2S |
Battery Volt-Amp-Hour Capacity |
692 |
Communication |
|
Audible Alarm |
Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm |
Control panel |
LED status display with load and battery bar-graphs and On Line : On Battery : Replace Battery : Overload and Bypass Indicators |
Emergency Power Off (EPO) |
Optional |
Interface Port(s) |
DB-9 RS-232, SmartSlot |
Available SmartSlot™ Interface Quantity |
1 |
Runtime |
|
Output power capacity |
2.1 KWatts / 3.0 kVA |
Surge |
|
Data Line Protection |
RJ-45 Modem/Fax protection (four wire dual line) |
Filtering |
Full time multi-pole noise filtering : 0.3% IEEE surge let-through : zero clamping response time : meets UL 1449 |
Physical |
|
Color |
Black |
Maximum Depth |
457 mm , 45.7 CM |
Maximum Height |
175 mm , 17.5 CM |
Net Weight |
34.0 KG |
Units per Pallet |
12.0 |
Rack Height |
4 U |
Shipping Depth |
597 mm , 59.7 CM |
Shipping Height |
337 mm , 33.7 CM |
Shipping weight |
37.7 KG |
Shipping Width |
622 mm , 62.2 CM |
Maximum Width |
432 mm , 43.2 CM |
Environmental |
|
Audible noise at 1 meter from surface of unit |
45.0 dBA |
Operating Temperature |
0 – 40 °C |
Operating Elevation |
0-3000 meters |
Operating Relative Humidity |
0 – 95 % |
Storage Temperature |
-20 – 50 °C |
Storage Elevation |
0-15000 meters |
Storage Relative Humidity |
0 – 95 % |
Online thermal dissipation |
652.0 BTU/hr |
Conformance |
|
Approvals |
EN 60950, EN/IEC 62040-1-1, EN/IEC 62040-2, IEC 60950, ISO 9001 |
Standard warranty |
2 years repair or replace, optional on-site warranties available, optional extended warranties available |
Sustainable Offer Status |
|
RoHS |
Compliant |