021-612 3131 / 0812 9726 3131 cs@platinum-computer.com
Select Page

Socomec MASTERYS IP+ RAIL CMI

Control and Monitoring Infrastructure UPS

gambar Socomec MASTERYS IP+ RAIL CMI

Socomec’s IP+ Rail CMI is the very latest in UPS technology for the mass transportation sector and has been engineered specifically to provide optimum energy efficiency for high performance critical power applications – in the most challenging operating environments.

Key Benefits
• Full Range 10-80 kVAIP Protection Degree : IP31standard or IP52 models available
• Coated Electronic Boards
• High Efficiency
• Full Galvanic Isolation
• Very Compact Unit
• London Underground Product Registration Certificate No: 1492
• Electromagnetic compatibility according to standard EN 50121

Designed for the most demanding applications
Housed in a compact, robust, steel-framed enclosure, the system has IP31 or IP52 ingress protection as well as anti-corrosion tropicalised circuit boards and a high electromagnetic disturbance immunity level. The system is also available in a version that is LU Section 12 compliant: this uses low smoke, zero halogen components and has surfaces painted in a finishing system compliant with London Underground specifications for use in sub-surface stations. The IP+ Rail range is the first UPS system to attain a London Underground Product Registration Certificate No: 1492

Easy integration into electrical infrastructure
• Input power factor > 0.99 and input current harmonic distortion < 3% thanks to IGBT rectifier.
• Galvanic isolation on input and output.
• Compatible with Open Vented Lead Acid, Valve Regulated Lead Acid (VRLA) and Nickel Cadmium batteries.
• User-friendly multilingual interface with graphic display.
• Flexible communication boards for every industrial communication need: dry contacts, MODBUS, PROFIBUS, etc.
• Fully compatible with generator sets.

Process continuity
• Frontal access for input/output cabling, spares replacement and preventative maintenance.
• Scalable power and high availability (using redundancy), with the facility to parallel up to 6 units.

For non-linear/unbalanced loads
• 100 % non-linear loads.
• 100 % unbalanced loads.
• 100 % “6-pulse” loads (motor speed drivers, welding equipment, power supplies…).
• Motors, lamps.

Standard electrical features
• Dual input mains. Galvanic isolation transformer.
• Internal maintenance bypass.
• Backfeed protection: detection circuit.
• EBS (Expert Battery System) for battery

Socomec’s specialist engineering team has the necessary training and accreditations to install and support your equipment throughout its lifecycle.

Standard electrical features
• Dual input mains.
• Internal maintanance bypass.
• Backfeed protection: detection circuit.
• EBS (Expert Battery System) for battery management.

Electrical options
• Long-life batteries.
• External battery cabinet (degree of protection up to IP32).
• External temperature sensor.
• Additional battery chargers.
• Additional transformer.
• Parallel kit.
• Cold start.
• ACS synchronization system.
• Neutral creation kit for mains without neutral.
• Tropicalization and anti-corrosion protection for electrical boards.

Standard communication features
• Multilanguage graphic display.
• Dry-contact interface.
• MODBUS/JBUS RTU.
• Embedded LAN interface (web pages, email).
• 2 slots for communication options.

Communication options
• Remote mimic panel.
• Profibus.
• MODBUS TCP.
• NET VISION: professional WEB/SNMP interface for UPS monitoring and shutdown management of several operating systems.

Remote maintenance
• LINK-UPS: maintenance software for continuous 24/7 monitoring of the SOCOMEC UPS.

Specifications MASTERYS IP+ RAIL CMI

Internal architecture

Energy storage option: ultracapacitor

Ultracapacitor could be a suitable battery replacement in special situations where a long back-up time is not required. This solution is targeted specifically to ride-through frequent voltage dips and short power outages, or simply bridge the startup of a generator, or where ambient temperatures could compromise battery lifetime. This would result in a highly reliable energy storage system that would require no maintenance.

Advantages

• Extremely long lifetime: 15 years with virtually unlimited cycling.
• High-reliability – No maintenance.
• Wide temperature range up to 45 °C.
• Ultra rapid charging.
• Battery-free, lead-free and environment-friendly

Technical data

Sn [kVA] 10 15 20 30 40 60 80
Pn [kW] – 3/1 9 13,5 18 27 32 48
Pn [kW] – 3/3 9 13,5 18 27 32 48 64
Parallel configuration(1) Available up to 6 units for power extension or redundancy
Efficiency Up to 95% in VFI –SS-11 mode TÜV verified (transformer excluded)
Input
Rated voltage 400 V (3ph + N)
Voltage tolerance ± 20%(3) (up to -40% @ 50% of rated power)
Rated frequency 50/60 Hz
Frequency tolerance ± 10%
Power factor / THDI(2) 0.99 / < 3%
Output
Rated voltage 1ph+n/2ph 230(220/240 configurable)(3)
3ph + N: 400 V (380/415 V configurable) (3)
Voltage tolerance ± 1%
Rated frequency 50/60 Hz
Frequency tolerance ± 2% (configurable from 1% to 8% with generator set)
Total output voltage distortion – linear load < 1 %
Total output voltage distortion – non-linear load < 5 %
Overload 125% for 10 minutes, 150% for 1 minute
Crest factor 3:1 (complying with IEC 62040-3)
Power factor without derating From 0.6 lagging up to 0.9 leading
Bypass
Rated voltage 1ph + N: 230 V, 3ph + N: 400 V
Voltage tolerance ± 15% (configurable from 10% to 20% with generator set)
Rated frequency 50/60 Hz
Frequency tolerance ± 2% (configurable from 1% to 8% with generator set)
Environment
Operating ambient temperature from 0 °C up to +40 °C (from 15 °C to 25 °C for maximum battery life)
Relative humidity 0 % – 95 % without condensation
Maximum altitude 1000 m without derating (max. 3000 m)
Acoustic level at 1 m
(ISO 3746)
< 52 dBA < 55 dBA < 65 dBA
Dimension and weight – UPS single cabinet
Dimensions (3/1) W x D x H 600 x 800 x 1400 mm 1000 x 835 x
1400 mm
Dimensions (3/3) W x D x H 600 x 800 x 1400 mm 1000 x 835 x
1400 mm
Weight (3/1) 230 kg 250 kg 270 kg 330 kg 490 kg 540 kg  –
Weight (3/3) 230 kg 250 kg 270 kg 320 kg 370 kg 500 kg 550 kg
Degree of protection IP31 and IP52 as option (according to IEC 60529) Coated electronic boards(4)
Colours RAL 7012
Standards
Safety EN 62040-1 (TÜV SÜD certified), EN 60950-1, LU 1-085 (Section 12 LU) (4)
Type and performance EN 62040-3 [VFI-SS-111]
EMC EN 62040-2 (2nd Edition) G-222 EN 50121
Product declaration CE

(1) With transformer on input/bypass side.
(2) For source THDV < 2 % and nominal load.
(3) Three-phase 220-230-240 V from 15 to 40 kVA.
(4) Section 12 version units only

Kata Kunci Terkait :

MASTERYS IP+ RAIL CMI, jual MASTERYS IP+ RAIL CMI, harga MASTERYS IP+ RAIL CMI, spesifikasi MASTERYS IP+ RAIL CMI, beli MASTERYS IP+ RAIL CMI, jual ups socomec

×

Platinum-Computer.Com

× Hubungi Kami