021-612 3131 / 0812 9726 3131 cs@platinum-computer.com
Select Page

APC Smart-UPS On-Line, 1000VA/1000W, 230V 

Gambar APC Smart-UPS On-Line, 1000VA/1000W, 230V (SRT1000RMXLI-NCITE)

Specifications APC (SRT1000RMXLI-NCITE)

Main
– Run time for load 1000 W Min-max: 100-1000 W 8min 27s
– Max. Capacity Used : 100 %
– Main Input Voltage : 230 V
– Main Output Voltage : 230 V
– Other Output Voltage : 220 V
– rated power in W : 1000 W
– Rated power in VA : 1000 VA
– Input Connection Type : BS1363A British
– output connection type : 6 IEC 60320 C13
– Number of rack unit : 2U
– Cable length : 1.83 m
– Number of cables : 1
– Battery type : Lead-acid battery
– Provided equipment : CD with software

Batteries & Runtime
– Run Time : View Runtime Graph
– Number of battery filled slots : 1
– Number of battery free slots : 0
– Battery recharge time : 3 h
– Battery voltage : 48 V
– Battery charger power : 97 W rated
– Battery power in VAH : 293 VAh runtime
– Battery life : 3…5 year(s)
– Battery option : SRT48RMBP 1 879 VAh
– Extended runtime : 1

General
– product web sub-family : High density
– Number of power module free slots : 0
– Number of power module filled slots : 0
– Redundant : No

Physical
– Colour : Black
– Height : 8.5 cm
– Width : 43.2 cm
– Depth : 50.5 cm
– Net weight : 21 kg
– Mounting preference : No preference
– Mounting mode : Rack-mounted
– Two post mountable : 0
– USB compatible : Yes
– Mounting position : Vertical

Input
– Network frequency : 40…70 Hz auto-sensing
– Input voltage limits : 176…275 V full load

Output
– Maximum configurable power in W : 1000 W
– Harmonic distortion : Less than 2 %
– Output frequency : 50/60 Hz +/- 3 Hz sync to mains
– Crest factor : 3 : 1
– UPS type : Double conversion online
– Wave type : Sine wave
– bypass type : Built-in bypass
– Maximum configurable power in VA : 1000 VA

Conformance
– Product certifications : CE

Environmental
– Ambient air temperature for operation : 0…40 °C
– Relative humidity : 0…95 % non-condensing
– Operating altitude : 0…10000 ft
– Ambient air temperature for storage : -20…50 °C
– Storage Relative Humidity : 0…95 % non-condensing
– Storage altitude : 0.00…15240.00 m
– Acoustic level : 50 dBA
– heat dissipation : 317 Btu/h
– IP degree of protection : IP20

Communications & Management
– Free slots : 0
– Preinstalled device : Network management card 3 with environmental monitoring
– Alarm : Audible and visible alarms : prioritized by severity
– Emergency power off : Yes

Surge Protection and Filtering
– Surge energy rate : 432 J

Packing Units
– Unit Type of Package 1 : PCE
– Number of Units in Package 1 : 1
– Package 1 Height : 24.6 cm
– Package 1 Width : 74.9 cm
– Package 1 Length : 59.4 cm
– Package 1 Weight : 29.6 kg

Contractual warranty
– Warranty : 3 years repair or replace (excluding battery) and 2 years for battery

×

Platinum-Computer.Com