APC Galaxy VS UPS 100kW 400V for external batteries, halogen-free cables, marine certified, Start-up 5×8

Specifications APC Galaxy VS UPS GVSUPS100KMHS

Overview
Presentation: Highly efficient, easy-to-deploy 100kW, 400V 3-phase UPS that brings best-in-class power protection and low total cost of ownership to edge, small and medium data centers, as well as to critical infrastructure in commercial and industrial applications. Includes 5×8 start-up service and halogen-free cables. Marine certified.
Lead time: Usually Ships within 2 Weeks

Main
Main Input Voltage: 400 V 3 phases
Other Input Voltage: 380 V, 415 V
Main Output Voltage: 400 V 3 phases
Rated power in W: 100 kW
Rated power in VA: 100 kVA
Battery type:
– External battery system
– Li-Ion (Lithium-Ion)
– VRLA
Provided equipment:
– Dust filter
– EcoStruxure IT ready (UPS)
– Installation guide
– Integrated network management
– Power modules ship installed
– Start-up service

Batteries & Runtime
Battery voltage: 480…576 V DC
Discharge battery voltage: 384 V DC
Max current discharge: 271 A
Battery power in VAH: 0 VAh runtime
Extended runtime: 0

General
Bypass voltage tolerance: +/- 10 %
Redundant: No

Physical
Colour: White
height: 148.5 cm
Width: 52.1 mm
Depth: 84.7 cm
Net weight: 250 kg
USB compatible: No

Input
Network frequency: 40…70 Hz
Input voltage limits: 340…460 V 400 V
Maximum input current: 180 A
Max short time withstand current: 65 kA
Input harmonic distortion: Less than 3 % for full load
Load power factor: From 0.7 leading to 0.7 lagging without any derating

Output
Maximum configurable power in W: 100 kW
Output frequency:
– 50 Hz sync to mains
– 60 Hz sync to mains
– 50 Hz +/- 0.1 % for 50 Hz nominal unsynchronised
– 60 Hz +/- 0.1 % for 60 Hz nominal unsynchronised
Crest factor: 2.5
Wave type: Sine wave
Output voltage tolerance: +/-1% after 50ms
Output harmonic distortion: < 1% linear load and < 5% non-linear load
Output overload operation: 10 minutes at 125% and 60 seconds at 150%
bypass type: Built-in static bypass
Maximum configurable power in VA: 100 kVA

Conformance
Standards:
– EN/IEC 62040-1
– EN/IEC 62040-2
– FCC part 15 class A
– IEC 60721-4-2 level 2M2
– UL 1778 5th edition

Environmental
ambient air temperature for operation: 0…40 °C
Relative humidity: 0…95 % non-condensing
Operating altitude: 0…3300 ft
Ambient air temperature for storage: -25…55 °C
Storage Relative Humidity: 10…80 % non-condensing
Acoustic level: 68 dBA
Heat dissipation: 11373 Btu/h
IP degree of protection: IP21

Communications & Management
control panel: Touch screen LCD user interface

Packing Units
Unit Type of Package 1: PCE
Number of Units in Package 1: 1
Package 1 Height: 168 cm
Package 1 Width: 99 cm
Package 1 Length: 64 cm
Package 1 Weight: 290 kg

Contractual warranty
Warranty: 1 year on-site repair or replace with factory authorized Start-Up

×