Socomec MASTERYS IP+ RAIL OLI

gambar ups-masterys-ip-rail-oli

MASTERYS IP+ RAIL OLI
Overhead Line Infrastructure UPS

Key Benefits
• Full Range 20-120 kVA
• IP Protection Degree: IP31 standard
• High Efficiency
• Coated Electronic Boards
• External Manual Bypass
• Low Smoke Zero Halogen option

Socomec’s IP+ Rail (OLI) offers increased energy availability: the system can take inputs from both a 25 kV overhead line as well as a 400V/230V mains supply.
As a result, this solution potentially avoids the need for a diesel generator and its associated maintenance, fuel storage and refuelling costs.
The innovative rectifier stage converts the input voltage into a DC voltage that will charge both the UPS battery and supply the input stage of the inverter.
In normal mode*, the upstream voltage of the rectifier corresponds to the transformed single phase voltage of the overhead line. The transformer and voltage stabiliser eliminates voltage sags and surges related to current draw of locomotives. When this voltage is not present or is no longer within tolerance, it is the 3 phase DNO supply which is sent directly to the UPS rectifier.
The inverter converts the DC voltage, provided either from the rectifier output or from the battery in a perfect sinusoidal voltage distributed to the critical loads.
The UPS is also equipped with an automatic bypass which allows a no-break transfer of the load directly onto the mains supply in case of overload or faults.
An external manual bypass completes the solution to allow for maintenance of the UPS.

Standard electrical features
• Dual input mains.
• Internal maintanance bypass.
• Backfeed protection: detection circuit.
• EBS (Expert Battery System) for battery management.

Electrical options
• Long-life batteries.
• External battery cabinet (degree of protection up to IP32).
• External temperature sensor.
• Additional battery chargers.
• Additional transformer.
• Parallel kit.
• Cold start.
• ACS synchronization system.
• Neutral creation kit for mains without neutral.
• Tropicalization and anti-corrosion protection for electrical boards.

Standard communication features
• Multilanguage graphic display.
• Dry-contact interface.
• MODBUS RTU.
• Embedded LAN interface (web pages, email).
• 2 slots for communication options.

Communication options
• Remote mimic panel.
• Profibus.
• MODBUS TCP.
• NET VISION: professional WEB/SNMP interface for UPS monitoring and shutdown management of several operating systems.

Remote maintenance
• LINK-UPS: maintenance software for continuous 24/7 monitoring of the SOCOMEC UPS.

Specifications ASTERYS IP+ RAIL OLI

Sn [kVA] 20 30 40 60 80 100 120
Pn [kW] – 3/1 18 27 32 48
Pn [kW] – 3/3 18 27 36 48 64 90 108
Parallel configuration(1) Available up to 6 units for power extension or redundancy
Efficiency Up to 95% in VFI –SS-11 mode TÜV verified (transformers excluded)
Input
Rated voltage 230V 1ph+n/2 ph coming from overhead line
400V 3ph+n coming from mains or generator
Voltage tolerance ± 20% (up to -40% @ 50% of rated power)
Rated frequency 50/60 Hz
Frequency tolerance ± 10%
Power factor / THDI(2) 0.99 / < 3%
Output
Rated voltage 3/1UPS 1ph+n/2ph 230(220/240 configurable ) (3)
Rated voltage 3/3UPS 3ph + N: 400 V (380/415 V configurable) (3)
Voltage tolerance ± 1%
Rated frequency 50/60 Hz
Frequency tolerance ± 2% (configurable from 1% to 8% with generator set)
Total output voltage distortion – linear load < 1 %
Total output voltage distortion – non-linear load < 5%
Overload 125% for 10 minutes, 150% for 1 minute
Crest factor 3:1 (complying with IEC 62040-3)
Power factor without derating From 0.6 lagging up to 0.9 leading
Bypass
Rated voltage 3/1 UPS 1ph + N/ 2ph: 230 V
Rated voltage 3/3 UPS 3ph + N: 400 V
Voltage tolerance ± 15% (configurable from 10% to 20% with generator set)
Rated frequency 50/60 Hz
Frequency tolerance ± 2% (configurable from 1% to 8% with generator set)
Environment
Operating ambient temperature from 0 °C up to +40 °C (from 15 °C to 25 °C for maximum battery life)
Relative humidity 0 % – 95 % without condensation
Maximum altitude 1000 m without derating (max. 3000 m)
Acoustic level at 1 m
(ISO 3746)
< 52 dBA < 55 dBA < 65 dBA
Dimension and weight – UPS single cabinet
Dimensions (3/1) W x D x H 600 x 800 x 1400 mm 1000 x 835 x
1400 mm
Dimensions (3/3) W x D x H 600 x 800 x 1400 mm 1000 x 835 x 1400 mm 700 x 835 x
1930 mm
Changeover cabinet Dimensions  W x D x H 800 x 835 x 1930 mm 1000 x 835 x 1930 mm 1600 x 835 x 1930 mm
Degree of protection IP31 and IP52 as option (according to IEC 60529) Coated electronic boards
Colours RAL 7012
Standards
Safety EN 62040-1 (TÜV SÜD certified), EN 60950-1
LOW SMOKE ZERO HALOGEN CABLES & CABINET COATING
EMC EN 62040-2 (2nd Edition) G-222 EN 50121
Performance EN 62040-3 [VFI-SS-111]
Product declaration CE

(1) With transformer on input/bypass side.
(2) For source THDV < 2 % and nominal load.
(3) Three-phase 220-230-240 V from 15 to 40 kVA.
More technical data on the dedicated sales document